Key Features

  • Automatic mains (utility) supply monitoring
  • Automatic shutdown when fault conditions are detected
  • Manual start
  • Engine pre-heat
  • Engine monitoring and protection features
  • Protected Solid State (PSS) outputs
  • Front panel mounting
  • Front panel programming
  • Tamper-proof engine hours counter
  • Remote start
  • LED indicators
  • Configurable timers
  • Configurable outputs
  • Single/three-phase mains sensing
  • Dimensions: 165mm x 125mm x 29mm (6.5 x 4.9 x 1.2); Cut-out Size: 149mm X 109mm (5.9 x 4.3)
  • Low cost
  • Low failure rate
  • Click Here To Download DSE704 User Manual

 11,000.00  12,500.00

Compare

DSE704 AMF Auto Mains Failure Controller

Buy all Deep Sea Genset controllers, energy meters, panel meters, synchronization controllers, auto mains failures (AMF), auto transfer switches (ATS), generator battery chargers, etc. in Pakistan. You can buy DSE704 Auto Genset Controller with a remote start option of Deep Sea online anywhere from Pakistan or by visitingElectronic Power House (EPH)andTetralink Technologies (TLT)in Lahore. We are the main distributors of Deep Sea in Pakistan. We have all original geneset controllers of Deep Sea ready in stock. All international & local brands of generator controllers are available at very reasonable and best prices in Pakistan.

Key Features

  • Automatic mains (utility) supply monitoring
  • Automatic shutdown when fault conditions are detected
  • Manual start
  • Engine pre-heat
  • Engine monitoring and protection features
  • Protected Solid State (PSS) outputs
  • Front panel mounting
  • Front panel programming
  • Tamper-proof engine hours counter
  • Remote start
  • LED indicators
  • Configurable timers
  • Configurable outputs
  • Single/three-phase mains sensing
  • Dimensions: 165mm x 125mm x 29mm (6.5 x 4.9 x 1.2); Cut-out Size: 149mm X 109mm (5.9 x 4.3)
  • Low cost
  • Low failure rate

Description

The DSE704 AMF controller is an Auto Mains Failure Control Module that offers an excellent range of engine monitoring and protection features. The module has been designed to monitor engine temperature, low oil pressure, fail to start, charge failure, over speed, and under speed. When the module detects a fault condition it automatically shuts down the engine. The module also includes two user-configurable auxiliary inputs.
The DSE4120 module includes all the features of the DSE704 plus a tamper-proof engine hours counter, engine exercise mode function and the enclosure has a closed back.
Both modules have been designed to automatically start the generator when the mains (utility) power fails. As soon as mains (utility) power is restored the modules have been designed to transfer the load back to the mains (utility) supply. The modules then instruct the engine to begin the cool down procedure and stopping sequence (user configured).

Module operation

OPERATION The modules are operated using the three push buttons on the front:
MANUAL(Hand Sign) This mode is used to manually start the engine.
AUTO (A) This mode is used to automatically start the engine. The module will be started by the remote start signal.
STOP(O) This button is used to stop the engine when it is running in either ma

Each alarm has its own indicator and once activated no further alarm conditions will be accepted. The alarm output and relevant LED will remain active until the unit reset by turning the switch to the O position.

Click Here To Download DSE704 Auto Genset Controller User Manual

color

Black

Technical Specifications

DC SUPPLY 8V to 35V:? continuous CRANKING DROPOUTS Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries.
MAXIMUM OPERATING CURRENT: 170mA(12V), 280mA(24V) (DSE4120 only) 50mA (DSE704 only)
TYPICAL CURRENT: 35mA(12V and 24V) (DSE 4120 only) 12mA (704 only)
ALTERNATOR INPUT RANGE: 75V(L-N) to 333V AC (L-N) absolute maximum
ALTERNATOR INPUT FREQUENCY: 50Hz ? 60Hz at rated engine speed (minimum:75V AC L-N) (Crank disconnect from 15V L-N @ 20Hz) Overspeed +14% (+24% overshoot) Underspeed -20%
START & FUEL OUTPUTS: 1.2 Amp DC at supply voltage. Switches to battery negative when active
AUXILIARY OUTPUTS: 1.2 Amp DC at supply voltage. Switches to battery negative when active
DSE704 DIMENSIONS: 165mm x 125mm x 29mm 6.5? x 4.9? x 1.2?
DSE704 CUT OUT: 149mm X 109mm 5.9? x 4.3?
DSE4120 DIMENSIONS: 171mm x 115mm x 49mm 6.7? x 4.5? x 1.9?
DSE4120 PANEL CUT OUT: 154mm x 98mm 6.1? x 3.9?
CHARGE FAIL: 8 Volt Charge Fail at 12 Volts, 16 Volt Charge Fail at 24 Volts