Buy all Stamford AVRs and Rotating Rectifier assemblies in Pakistan. You can buy MX321 Stamford AVR with Soft Shell for Stamford Generatoronline anywhere from Pakistan or by visitingElectronic Power House(EPH) andTetralink Technologies(TLT) in Lahore who are the main distributor of Stamford in Pakistan. All original Stamford products are available at very reasonable and best prices in Pakistan
Key Features:
- MX321 AVR adjustment rate is better than 0.5%
- High-quality generator voltage regulator
- Long service life
- Built-in low-speed protection
- Over excitation protection
- Over-voltage protection
- Over-current protection
- LAM Protection
- Professional manufacturing
- Exquisite workmanship
- High reliability
- High-quality capacitor and terminal
- Superior performance
General description
MX321 Stamford AVR is a three-phase sensed Automatic Voltage Regulator and forms part of the excitation system for a brush-less generator. Excitation power is derived from a three-phase permanent magnet generator (PMG), to isolate the AVR control circuits from the effects of nonlinear loads and to reduce radio frequency interference on the generator terminals. Sustained generator short circuit current is another feature of the PMG system.
The AVR senses the voltage in the main generator winding and controls the excitation to maintain the generator output voltage within the specified limits, compensating for load, speed, temperature, and power factor of the generator. Three-phase RMS sensing is employed for superior voltage regulation.
Adjustable Soft start circuitry is included to provide a smooth controlled build-up of the generator output voltage.
A frequency measuring circuit continually monitors the shaft speed of the generator and provides under-speed protection of the excitation system by reducing the generator output voltage proportionally with speed below a pre-settable threshold. A further enhancement of this feature is an adjustable volt per Hertz slope and voltage recovery time, to improve the response of turbocharged engines.
Current limiting may be included to allow control over the amount of sustained short circuit current.
Maximum excitation is limited to a safe period by the internal shutdown of the AVR output device. This condition remains latched until the generator has stopped.
The AVR includes an over-voltage protection feature with an internal shutdown of the AVR output device, plus the ability to trip an optional excitation circuit breaker if required. Provision is made for the connection of a remote voltage trimmer, allowing the user fine control of the generator’s output.
An analogue input is provided allowing connection to a Newage Power Factor controller or other external devices with compatible output.
The AVR has the facility for droop CT connection, to allow parallel running with other similarly equipped generators.