Growatt Service Centre Lahore

Growatt Solar Inverter Troubleshooting: Authorized Growatt Service Center Lahore Leave a comment

Growatt Solar Inverter Troubleshooting: Authorized Growatt Service Center Lahore

Growatt solar inverters are renowned for their efficiency and reliability in harnessing solar energy. However, like all sophisticated equipment, they may occasionally encounter issues that require professional attention. In Lahore, Tetralink Technologies stands as the Authorized Growatt Service Center Lahore, offering expert solutions to ensure your system operates seamlessly.

Why Choose Tetralink Technologies?

  • Authorized Growatt Service Center Lahore: Tetralink Technologies is officially recognized by Growatt, ensuring that your inverter is serviced according to the manufacturer’s standards.
  • Expert Engineers: Our team has undergone specialized training in China, equipping them with the skills to diagnose and repair Growatt inverters effectively.
  • Genuine Parts: We use only original Growatt components, guaranteeing the longevity and reliability of your inverter post-repair.
  • Avoid Unqualified Repairs: Entrusting your inverter to unqualified electricians can lead to improper handling, voided warranties, and further complications.

Common Growatt Inverter Error Codes and Recommended Actions

Understanding the error codes displayed by your Growatt inverter can provide insight into potential issues. Below is a table summarizing common error codes, their descriptions, and suggested actions:

Here is the comprehensive table of Growatt inverter error codes, descriptions, and troubleshooting steps:

Error Code Description Troubleshooting
No AC Connection No utility grid connected or utility grid power failure Check your AC isolator or circuit breaker. If both the isolator and circuit breaker are ‘on’ and the problem persists, submit a maintenance service request.
AC V Outrange Utility grid voltage is out of permissible range This could occur during peak summer months when solar activity is high. If the problem persists, submit a maintenance service request.
AC F Outrange Utility grid frequency is out of permissible range This could occur during peak solar production months. If the problem persists, submit a maintenance service request.
Over Temperature Temperature out of range Restart the inverter. Ensure it is not covered or in direct sunlight causing overheating. If the issue persists, contact Growatt.
PV Isolation Low Insulation problem Submit a maintenance service request to your installer.
Output High DCI Output current DC offset too high Restart the inverter. If the issue persists, submit a maintenance service request.
Residual I High Leakage current too high Restart the inverter. If the problem persists, submit a maintenance service request.
PV Voltage High DC input voltage exceeds maximum tolerable value Disconnect the DC switch immediately and turn off the system. Submit a maintenance service request.
Auto Test Failed Auto test did not pass Restart the inverter. If the issue persists, contact Growatt.
100 Voltage fault Submit a maintenance service request to your installer.
101 Communication fault Turn off the DC switch and restart the inverter. If the problem persists, submit a maintenance service request.
102 Master and slave processor data mismatch Turn off the DC switch and restart the inverter. If the problem persists, submit a maintenance service request.
116 EEPROM fault Restart the inverter. If the fault is sustained, the control board may need replacement. Contact Growatt.
117 Relay fault Restart the inverter. If the issue persists, submit a maintenance service request.
118 Init model fault Submit a maintenance service request to your installer.
119 GCFI device damage Restart the inverter 2-3 times. If the issue persists, submit a maintenance service request.
120 HCT fault Restart the inverter. If the problem persists, submit a maintenance service request.
121 Communication fault between master and slave See error codes 101 and 102 for troubleshooting steps.
122 Bus voltage fault Submit a maintenance service request to your installer.
201 Leakage current too high Restart the inverter. If the error persists, contact Growatt.
202 DC input voltage exceeds maximum tolerable value Disconnect the DC switch immediately. Use a multimeter to check the voltage of each PV string. If voltage is lower than 550V, contact Growatt.
203 Insulation problem Check if the panel and inverter are grounded properly. Check for wet DC breakers. Ensure impedance between PV(+) and PV(-) to ground is within range. If the problem persists, contact Growatt.
300 Utility grid voltage out of permissible range Switch off the DC switch. Check AC wiring, neutral, and ground connections. Verify grid voltage compliance. Restart the inverter. If the issue persists, contact Growatt.
302 No AC connection Check AC wiring and the status of the AC breaker.
304 Utility grid frequency out of permissible range Switch off the DC switch. Check AC wiring, neutral, and ground connections. Verify grid frequency compliance. Restart the inverter. If the issue persists, contact Growatt.
303 Voltage of Neutral and PE exceeds 30V Check the voltage of Neutral and PE. Verify AC wiring. Restart the inverter. If the problem persists, contact the manufacturer.
407 Auto test failed Restart the inverter. If the issue persists, contact Growatt.
203 Warning PV circuit short Check PV panel polarity and restart the inverter. If the problem persists, contact Growatt to replace the power board.
204 Warning Dry connect function abnormal Check dry connect wiring after shutting down. If the issue persists, contact the manufacturer.
205 Warning PV boost circuit broken Restart the inverter. If the problem persists, contact Growatt to replace the power board.
207 Warning USB over-current Unplug the USB or monitor. Reconnect after shutdown. If the error persists, contact the manufacturer.
401 Warning Meter communication abnormal Check if the meter is powered on. Verify connections between the inverter and the meter.
404 Warning EEPROM abnormal Restart the inverter. If the problem persists, contact Growatt to replace the M3 board.
405 Warning Firmware version inconsistent Update to the correct firmware version.
402 Error Output High DCI Restart the inverter. If the issue persists, contact Growatt.
404 Error Bus sample fault Restart the inverter. If the problem persists, contact Growatt.
405 Error Relay fault Restart the inverter. If the problem persists, contact Growatt.
408 Error Over temperature If the ambient temperature is below 60°C and the error persists after restarting, contact Growatt.
409 Error Bus over-voltage Restart the inverter. If the problem persists, contact Growatt.
411 Error DSP-M3 communication fault Restart the inverter. Update DSP and M3 firmware. If the problem persists, replace the DSP or M3 board and contact Growatt.
414 Error EEPROM fault Restart the inverter. If the problem persists, contact Growatt.
417 Error Data mismatch between DSP and redundant M3 Restart the inverter. If the problem persists, contact Growatt.
420 Error GFCI fault Restart the inverter. If the problem persists, replace the power board or contact Growatt.