Key Features

  • Manual and remote starting and stopping
  • Zero power consumption at rest
  • Engine control mode available
  • Generator protection
  • Built-in alarms and warnings
  • 1 phase Genset voltage input
  • 1 phase Genset CT input
  • Engine oil pressure measurement
  • Engine coolant temperature measurement
  • Engine fuel level measurement
  • Genset active power measurement (single phase)
  • Genset power factor measurement (single phase)
  • Periodic maintenance request indicator
  • Engine hours run counter
  • Plug-in connection system for easy replacement
  • Small dimensions (96x96x53mm)
  • Low cost
  • Click Here To Download DKG215 User Manual

 50,000.00  55,000.00

Compare

Buy all Datakom products like generator controllers, energy meters, panel meters, synchronization controllers, auto mains failures (AMF), auto transfer switches (ATS), generator battery chargers etc, online in Pakistan. You can buy DKG215 maual & remote start unit online or by visiting Electronic Power House (EPH) and Tetralink Technologies (TLT) in Lahore who are the authorized distributor of Datakom in Pakistan. All original Datakom products are available at very reasonable and best prices in Pakistan.

Features

  • Manual and remote starting and stopping
  • Zero power consumption at rest
  • Engine control mode available
  • Generator protection
  • Built-in alarms and warnings
  • 1 phase Genset voltage input
  • 1 phase Genset CT input
  • Magnetic Pickup input
  • Engine oil pressure measurement
  • Engine coolant temperature measurement
  • Engine fuel level measurement
  • Genset active power measurement (single phase)
  • Genset power factor measurement (single phase)
  • Periodic maintenance request indicator
  • Engine hours run counter
  • Event logging
  • Statistical counters
  • Front panel configurable
  • 100+ adjustable parameters
  • Logic level serial port
  • Optional RS-232 adapter
  • Free MS-Windows Remote monitoring SW:
    -monitoring
    -download of parameters
  • LED displays
  • Configurable analog inputs: 3
  • Configurable digital inputs: 5
  • Digital outputs: 5
  • Survives cranking dropouts
  • Sealed front panel
  • Plug-in connection system for easy replacement
  • Small dimensions (96x96x53mm)
  • Low cost

Modes Of Operation

The unit will power-up when the front panel RUN button is pressed. It will turn-off if the STOP button is pressed. If no key is pressed it will power down automatically after approximately 4 minutes. If needed, the automatic power-down feature may be disabled with the program parameter P_37. When the unit is powered up, if the RUN button is pressed again, then the Genset will run. When the engine is running the GENERATOR led will flash. When the Genset is ready for load, it will turn on steadily. If the STOP button is pressed the Genset will stop, but the unit will stay powered-up. If the STOP button is pressed again or no key is pressed for 4 minutes then it will power-down automatically. If an alarm occurs during any operation status, the Genset will stop and the related alarm led will turn on steadily. The unit will not power down until the alarm is canceled with the STOP button. If AUTO mode is selected, then the REMOTE START (11) input is enabled. It does not need any programming. Please check chapter 6.1 for the remote start operation.

 

Click Here To Download DKG215 User Manual

Technical Specifications

color

Black

Technical Specifications

Alternator voltage: 15 to 300 V-AC (Ph-N) Alternator frequency: 0-100 Hz. Current input: from current transformer, …/5A. Max load 0.7VA Digital inputs: input voltage 0 – 30 V-DC. Internally connected to battery positive via 4700 ohm resistor. Analog inputs: Resistor input 0 to 5000 ohms connected to the battery negative. Sources 10 mA when closed to battery negative. Magnetic pickup input: 1-30V-AC, 0 to 10 KHz. Measurement category: CAT II Air category: Pollution degree II DC Supply range: 9.0 V-DC to 33.0 V-DC Cranking dropouts: survives 0 V for 100ms Typical standby current: 0 mA-DC Maximum operating current: 100 mA-DC (digital outputs open) Digital outputs: 1A / 28 V. Negative pulling protected semiconductor outputs. Charge alternator excitation current: 150 mA-DC minimum. Serial port: Logic levels. 2400 bauds, no parity, 1 bit stop. Operating temperature range: -20?C to +70?C (-4 ?F to +158 ?F) Storage temperature range: -30?C to +80?C (-22 ?F to +176 ?F) Maximum humidity: 95%, non-condensing IP protection: IP65 from front panel, IP30 from the rear Dimensions: 96 x 96 x 53mm (WxHxD) Panel Cut-out dimensions: 91 x 91mm minimum. Mounting: Front panel mounted with rear retaining plastic brackets Weight: 170 g (approx.) Case material: High temperature, self extinguishing ABS (UL94-V0)